![]() If one is A and one is B, the light will be off. If both switches are in the A (or both B) position, the light will be on. 3-way switches are basically A/B switches. The MACL-153 and MA-600 connections are exactly the same. I cannot get to the wiring to actually see how it is wired, however. other than the fact that there are two lighting sources, rather than one bulb as the diagram pictures. I would expect that the wiring of the circuit looks like this: Something must be wired oddly at the MR16/outlet which powers the LED rope which is preventing these dimmers from being wired in place of the rockers - but I don't know what. Continuity testing between switch locations verifies both the white and the red as traveler wires red to red and white to white. Testing the wires into each gang box results in finding that only one of the gang boxes has a hot black as I would have expected. I've tried swapping the white and red wire locations, first only on one, and then both: no effect behavior is the same. Holding down the main button on the MA-R results in slight brightening of the LED rope that's the only effect either switch has on the rope other than using the FASS. No green LED has ever lit up on either the MA-153M or MA-600 master the LED rope lighting lights up dimly, however - and if I pull the FASS switch on either side of the MA-600 master/slave option (which I tried only to eliminate the possibility that I was dealing with a defective MA-153M), the LED rope light turns off. I'm aware that the wiring is different for each option (using the 153M requires two wires be joined at the original switch location), and I've tried variations, all with no effect. I have two different Lutron switch options: the MA-153M dimmer, which I intended to use with one of the existing rockers, or a MA-600 with a MA-R slave. Circuit works fine with original rocker switches.īoth rocker switches were wired exactly the same: each had a black wire connected to the black screw white to the same-side brass screw, and a red wire connected to the opposite side screw. I replaced the LED rope light with a new strand (old one had burnt out sections). The rope lighting plugs into a hidden outlet which is switched by the circuit. I have a 3 way circuit controlling a 120v rope lighting feature, as well as a halogen MR16 uplight on a fireplace mantel. My entire house is Lutron Maestro MA-600 and MA-1000 dimmers, so I'm familiar. Pretty much at my wit's end with this problem.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |